Laminar
Air flow Cabinet (LAF)
Whitenair is a Leading manufacturer of premium laminar Flow Cabinet( LAF) for a diverse
range of industry such as Life science, Biotech, Medical, Pharmaceuticals,
Research labs , semiconductor ,Electronic, aerospace etc .etc. whitenair has
installed thousands of LAF’s providing reliable protection for samples and work
process for a multitude of applications. whitenair offering a combination of
value, high quality construction, low operating cost and a wide product range
to suit all your requirement and budgets.
Based
on the Air flow they are two types
1) Whitenair
Horiontal LAF
Whitenair
Horizontal Laminar Flow Clean Bench offers proven protection for your samples
and process. This models offers a sensible balance of Quality and performance
fetures. Like all whitenair products this model also features many key
innovations for which whitenair is recognized, Mini-pleated separator less ULPA
/HEPA filter technology, the best product protection in the world, External
rotor induction motor, superior modular construction and assembly.
Whitenair
Horizontal laminar Flow cabinets are available in Three Versions: E series, S Series, D series
1.1 Whitenair E series Horizontal Laminar Flow Cabinet
Key benefits:
1)
Modular Construction
2)
Knockdown Design
3)
ISO Class 3 or Class 5 work Zone
4)
Low noise and vibration
5)
Superior air Flow Uniformity
6)
MOC Available in : EPCGI ,SS304,SS 316
7)
Transparent Side Glass
Screen.
8)
Transparent UV resistant
Foldable Idle Doors
9)
Analogue Static Pressure
Gauge
10)
H13 grade HEPA Final Filter
Dimensional Chart E Series
Over
all Sizes
|
Internal working Zone size
|
|||||
Product
Code
|
L
|
D
|
H
|
L1
|
D1
|
H1
|
WHL 2000E
|
695
|
1050
|
1475
|
600
|
600
|
600
|
WHL 3000E
|
1000
|
1050
|
1475
|
900
|
600
|
600
|
WHL 4000E
|
1300
|
1050
|
1475
|
1200
|
600
|
600
|
WHL 6000E
|
1915
|
1050
|
1475
|
1800
|
600
|
600
|
*All Dimensions are in
mm ** Custom sizes available on request
1.2 Whitenair S
series Horizontal Laminar
Flow Cabinet
Key benefits:
1)
Modular Construction
2)
Knockdown Design
3)
ISO Class Class 5
work Zone
4)
Low noise and vibration
5)
Superior air Flow Uniformity
6)
MOC Available in : EPCGI ,SS304,SS 316
7)
Transparent Side Glass
panels
8)
Transparent UV resistant
Foldable Idle Doors
9)
Digital Static pressure
Gauge
10)
Micro controller based Operation
11)
H14 grade Mini-pleated HEPA
Final Filters
Dimensional Chart S Series
Over
all Sizes
|
Internal working Zone size
|
|||||
Product
Code
|
L
|
D
|
H
|
L1
|
D1
|
H1
|
WHL
300S
|
1060
|
880
|
2150
|
980
|
620
|
700
|
WHL
400S
|
1365
|
880
|
2150
|
1200
|
620
|
700
|
WHL
600S
|
1915
|
880
|
2150
|
1800
|
620
|
700
|
*All Dimensions are in mm ** Custom sizes available on request
1.3 Whitenair D series Horizontal Laminar Flow Cabinet
Key benefits:
1)
Modular Construction
2)
Knockdown Design
3)
Power Saving Design
4)
ISO Class Class3 class 5 work Zone
5)
Low noise and vibration
6)
Superior air Flow Uniformity
7)
Continuous Air Flow
Monitoring
8)
MOC Available in : Combination of EPCGI/ SS304, SS 304,SS
316
9)
Transparent Side Glass
panels
10)
Transparent UV resistant
Vertical sliding Doors
11)
Digital Static pressure
Gauge
12)
Micro controller based Operation
13)
Imported UV Lamp & UV
Life Meter
14)
High efficient External
Rotor Blower
15)
H14 grade HEPA / ULPA Final Filters
16)
LED Light Panels
Dimensional Chart D Series
Over
all Sizes
|
Internal working Zone size
|
|||||
Product
Code
|
L
|
D
|
H
|
L1
|
D1
|
H1
|
WHL
30D
|
1060
|
930
|
2150
|
980
|
620
|
700
|
WHL
40D
|
1365
|
930
|
2150
|
1200
|
620
|
700
|
WHL
60D
|
1915
|
930
|
2150
|
1800
|
620
|
700
|
*All Dimensions are in
mm ** Custom sizes available on requ
2) Whitenair Vertical
LAF
Whitenair
Verical Laminar Flow Clean Bench offers proven protection for your samples and
process. Vertical LAF offers certain tangible advantages over Horizontal LAF ,
such as low Energy consumption,Less Airflow turbulence especially when large
objects are used in the work zone..
General Features:
Ć¼ ULPA and HEPA Filters tested to
atypical efficiency of > 99.999%
for0.1 to 0.3 micron and 99.995% for 0.3 micron respectively
Ć¼ All Whitenair Laminar flow provide
class3/class5 air cleanliness with in the work zone as per ISO 14644.1.
Ć¼ A cleanable Pre Filter traps large particles in the in flow air prior to
reaching the mail filter protecting against damage and prolonging Final filter Life
Ć¼ All Whitenair products are manufactured for the most demanding
laboratory applications. All components designed for maximum chemical
resistance and enhanced durability the main body of the cabinet is constructed
of Electro galvanized steel or PVC film protected pre finished SS of 304 or 316
grade
Ć¼ Built in electronic ballast lighting provides excellent illumination of
the work zone and reduce operator fatigue. The reliable lighting system is zero
flicker and instant start
Ć¼ Whitenair Laminar Flow benches have been tested for cross contamination
and product protection using microbiological test methods specified in EN 12469
Ć¼ Each LAF clean Bench is individually factory tested for safety and
performance in accordance with international standards.
Ć¼ Most of the Electrical components are ISIor CE listed ensuring superior electrical safety
for operator.
Whitenair Vertical laminar Flow cabinets are available
in Three Versions: E series, S Series, D
series
2.1 Whitenair E series
Vertical Laminar Flow Cabinet
Key benefits:
1)
Modular Construction
2)
Knockdown Design
3)
ISO Class 3 or Class 5 work Zone
4)
Low noise and vibration
5)
Superior air Flow Uniformity
6)
MOC Available in : EPCGI ,SS304,SS 316
7)
Transparent Side Glass
Screen.
8)
Transparent UV resistant
Foldable Idle Doors
9)
Analogue Static Pressure
Gauge
10)
H13 grade HEPA Final Filter
Dimensional Chart E series
Over
all Sizes
|
Internal working Zone size
|
|||||
Product
Code
|
L
|
D
|
H
|
L1
|
D1
|
H1
|
WVL 2000E
|
750
|
750
|
2050
|
650
|
600
|
600
|
WVL
3000E
|
1050
|
750
|
2050
|
950
|
600
|
600
|
WVL
4000E
|
1350
|
750
|
2050
|
1250
|
600
|
600
|
WVL
6000E
|
1950
|
750
|
2050
|
1850
|
600
|
600
|
*All Dimensions are in mm **Custom sizes available on request
2.2 Whitenair S
series Vertical Laminar
Flow Cabinet
Key benefits:
1)
Modular Construction
2)
Knockdown Design
3)
ISO Class Class 5
work Zone
4)
Low noise and vibration
5)
Superior air Flow Uniformity
6)
MOC Available in : EPCGI ,SS304,SS 316
7)
Transparent Side Glass
panels
8)
Transparent UV resistant
Foldable Idle Doors
9)
Digital Static pressure
Gauge
10)
Micro controller based Operation
11)
H14 grade Mini-pleated HEPA
Final Filters
Dimensional Chart S Series
Over
all Sizes
|
Internal working Zone size
|
|||||
Product
Code
|
L
|
D
|
H
|
L1
|
D1
|
H1
|
WVL
300S
|
1050
|
750
|
2150
|
950
|
700
|
700
|
WVL
400S
|
1350
|
750
|
2150
|
1250
|
700
|
700
|
WVL
600S
|
1950
|
750
|
2150
|
1850
|
700
|
700
|
All Dimensions are in mm **Custom sizes available on request
1.3 Whitenair D series Vertical Laminar Flow Cabinet
Key benefits:
1)
Modular Construction
2)
Knockdown Design
3)
Power Saving Design
4)
ISO Class Class3 class 5 work Zone
5)
Low noise and vibration
6)
Superior air Flow Uniformity
7)
Continuous Air Flow
Monitoring
8)
MOC Available in : Combination of EPCGI/ SS304, SS 304,SS
316
9)
Transparent Side Glass
panels
10)
Transparent UV resistant
Vertical sliding Doors
11)
Digital Static pressure
Gauge
12)
Micro controller based Operation
13)
Imported UV Lamp & UV
Life Meter
14)
High efficient External
Rotor Blower
15)
H14 grade HEPA / ULPA Final Filters
16)
LED Light Panels
Dimensional Chart D Series
Over
all Sizes
|
Internal working Zone size
|
|||||
Product
Code
|
L
|
D
|
H
|
L1
|
D1
|
H1
|
WVL
30D
|
1060
|
800
|
2150
|
980
|
620
|
700
|
WVL
40D
|
1365
|
800
|
2150
|
1200
|
620
|
700
|
WVL
60D
|
1915
|
800
|
2150
|
1800
|
620
|
700
|
*All Dimensions are in
mm ** Custom sizes available on request